info@bjmadan.com +91 9811408330  

Precision Oncology

Diagnostic Radioisotopes

B. J. Madan & Co. is the authorized agent for ITM Medical Isotopes GmbH, Germany in India.

  • ITM 68Ge/68Ga GENERATOR

68Ga PET imaging has proven to be a superior method for precise localization of tumor cells and metastatic lesions. With the GMP certification of our ITM 68Ge/68Ga Generator we have set yet another milestone in order to establish 68Ga as next generation radioisotope for diagnostic purpose. The generator columns unique metal free design and its low acidic eluent allow the fast and convenient onsite production of short-lived high-quality 68Ga for radiolabeling without prior prepurification.

KEY ADVANTAGES

  • Fast and convenient labelling of PET tracers
  • Metal free matrix allows direct labelling
  • Low acidic eluent (0.05 M HCl)
  • Small elution volume (4ml)

Download Brochure

  • Targeted Radionuclide Therapy in Precision Oncology

Precision oncology has made progress in leaps and bounds in recent years and is currently at the heart of revolutionizing cancer research. As this research continues to develop and evolve, the enhanced use of precision oncology in cancer treatment ultimately aims to improve prognosis and outcomes for patients. Precision Oncology is an innovative approach to cancer treatment that ensures the treatment is specifically designed and targeted to the unique form of cancer.

Peptide Receptor Radionuclide Therapy (PRRT) a form of molecular targeted therapy is performed by using a small peptide that is coupled with a radionuclide. PRRT is a novel nuclear medicine therapy for the systemic treatment of metastasized tumors.

  • EndolucinBeta® – n.c.a. 177 Lu Chloride

EndolucinBeta® 40 GBq/mL Radiopharmaceutical Precursor Solution.
EndolucinBeta® is a radiopharmaceutical precursor used in Targeted Radionuclide Therapy for the treatment of various diseases, like cancer. When labeled with a disease-specific carrier molecule (e.g. peptide or antibody), the targeted radiopharmaceutical binds to a tumor specific receptor, according to the lock and key principle. EndolucinBeta® has a half-life of 6.647 days.

Active substance: no-carrier-added (n.c.a.) Lutetium-177 (177Lu) chloride

Marketing Authorization Holder: ITM Medical Isotopes GmbH. A company of the ITM Group.

Package leaflet: Information for the patient
Additional information for Healthcare Professionals

www.itm-radiopharma.com/

Download Brochure

  • Actinium-225

Alpha Emitter with short Penetration Range
Actinium-225 (225Ac) is an alpha-emitting radioisotope with a half-life of 9.920 days. It is characterized by an extremely short penetration range of alpha particles and a high linear energy transfer (LET).
225Ac is delivered in 2 mL V-shape vial as a solution in 0.1 M hydrochloric acid with a Chemical purity: > 99.9 % 225Ac

  • 188W/188Re Generator

B. J. Madan & Co. is the authorized agent for OncoBeta Gmbh, Germany in India.

Production of high-energy beta emitting rhenium-188

Product Overview
The OncoBeta® 188W/188Re Generator is based on an alumina column. The longer-lived mother radionuclide 188W is adsorbed on the column material while the daughter radionuclide 188Re is selectively eluted from the generator with sterile isotonic solution as sodium perrhenate (Na188ReO4).

Use Cases
The 188W/188Re Generator can be used for radiolabelling reactions or directly as a high dose liquid radioactive source.

Main Features
> Available in different sizes upon request up to 150 GBq (4 Ci) 188W
> High activity concentration > Up to 9 GBq/ml

https://www.oncobeta.com/wolfram-rhenium-generator-de/

Specifications

Column materialAluminium oxide (Al2O3) packed in quartz glass column
EluentSterile 0.9% saline solution
Chemical formSodium perrhenate (Na188ReO4)
AppearanceClear and colorless solution
Elution volume5-14 ml (with small volumes not completed elution)
Elution yield75-85%
Radiochemical purity>98% Re(VII)
Tungsten breakthrough188W <0.01% in relation to 188Re at calibration time
Total gamma impurities<0.01% in relation to 188Re at calibration time
Shelf-life10 months
Specific activityProduct is carrier free
Generator size (nominal 188W activity)3.7-150 GBq
Generator dimensionsDiameter 145 mm, height 210 mm
Generator weight16 kg
Interface StandardStainless steel needles for elution with evacuated vials. On request: Tubings with Luer-Lock connectors (inlet female, outlet male)

  • Sodium Iodide I-131 solution

Radioactive Iodine (I-131) Therapy. Radioiodine therapy is a nuclear medicine treatment for an overactive thyroid, a condition called hyperthyroidism, and also may be used to treat thyroid cancer.